M6L-9X magnetic field shielding foil for large-scale shielding of low-frequency magnetic fields. Highly resistant due to high-quality lamination and extremely flexible in application, whether in domestic environments or for large areas in construction, commerce, or industry.
M6L-9X is a magnetic field shielding foil designed for the mitigation of low-frequency magnetic fields. By combining 6 ultra-thin shielding foils, a higher protective effect is achieved compared to a single thick plate. The double-sided lamination makes the material highly resistant and ideal as an intermediate layer for roof or floor constructions. While single-layer application offers an optimal price-performance ratio, multi-layering can be used for higher magnetic flux densities.
Previously available only in fixed plate dimensions, the material is now available as flexible roll stock in linear meters. One roll has a maximum length of 18 meters. This allows for versatile use on small surfaces in private settings as well as on large areas in construction, commerce, or industry. Numerous application possibilities also exist in the field of mobility, such as in electric vehicles (EVs), vans, motorhomes, and caravans.
Applications of the M6L Series
Due to the 90 cm width and availability as a roll in linear meters, the material is ideally suited for large areas in domestic settings as well as in construction, commerce, or industry.
Furthermore, there are diverse application possibilities in cars, electric vehicles, vans, motorhomes, and caravans.
- High Shielding Performance: Up to 33 dB attenuation against magnetic fields – one layer is sufficient for simple applications, while multiple layers can be used for strong fields.
- Easy Processing: Simple application using scissors, adhesive, or staplers, along with the option for grounding, makes it universally applicable.
Technical Details for M6L Magnetic Field Shielding Foil
- Width: 90 cm (Shielding area) | 94 cm (Total product incl. foil edge)
- Length: Available by the meter | 18 m roll
- Thickness: 1 mm
- Magnetic Field Shielding (Three-phase 50 Hz)
- Single-layer: 19,5 dB (89,4%)
- Double-layer: 25,7 dB (94,8%)
- Triple-layer: 30,2 dB (96,9%)
- Quad-layer: 32,6 dB (97,7%)
- Magnetic Field Shielding (Single-phase 50 Hz):
- Single-layer: 17,7 dB (87%)
- Double-layer: 23,2 dB (93,1%)
- Triple-layer: 26,8 dB (95,4%)
- Quad-layer: 29,3 dB (96,6%)
- Magnetic Field Shielding (Static): DC consumers, Earth’s magnetic field, and permanent magnets are shielded in a range from 15% (single-layer) up to 58% (quad-layer).
- Minimum Bending Radius: 20 cm
- Ingredients and specific magnetic parameters are not declared for reasons of innovation.
Processing the M6L Shielding Series
Caution: Risk of injury from cuts!
The M6L series can be cut using high-quality scissors. The cut edges are sharp as a knife and must be protected immediately after cutting, for example, with fabric adhesive tape. Cut-resistant gloves must be worn during processing!
Ideally, the installation should be planned so that cutting is minimized.
When applied to large wall surfaces, it should be noted that the foil acts as a vapor barrier.
Processing with Adhesive:
An adhesive capable of bonding the PET (polyethylene terephthalate) lamination film should be selected. High-viscosity construction adhesives are available for solid surfaces, or flexible plastic adhesives for applications such as under car carpets. The instructions of the adhesive manufacturer must be followed.
Processing via Stapler or Nailer:
On suitable substrates, installation with an electric stapler or nailer is recommended. For a single layer including overlap, a medium-priced electric stapler is sufficient; for two or more layers, a professional nailer is required. The shielding surface must overlap by at least 2 cm.
Multi-layer Installation:
Foil layers should always be installed in a staggered manner, ensuring that the surfaces cover underlying overlaps.
FAQ | Frequently Asked Questions
The foil is used for the targeted shielding of low-frequency magnetic fields. By using highly effective alloys, magnetic flux densities are reduced, which is particularly relevant near transformers, power lines, or in electric vehicles.
Physically, multiple thin layers achieve significantly higher shielding attenuation than a single solid plate of the same thickness. The combination of 6 ultra-thin special foils optimizes magnetic conductivity and thus the shielding result.
The material can be cut to size using high-quality scissors. Installation is carried out by gluing, stapling, or nailing, depending on the substrate. Due to sharp cut edges, the use of cut-resistant gloves and subsequent taping of the edges is mandatory.
The availability as roll stock up to 18 linear meters allows for continuous installation on large areas. This reduces butt joints and gaps caused by cutting, increasing efficiency in construction, industry, or vehicle lining.
The foil is applied in private residential environments (floor and roof constructions), commercial buildings, and vehicle construction. Especially in electric vehicles, motorhomes, and vans, it provides protection against magnetic fields from the integrated electronics and battery technology.
Yes, for areas with particularly high magnetic flux densities, multi-layer installation is recommended. The layers should be laid staggered to completely cover the overlaps of the layers underneath and maximize shielding performance.
Test Report & Expert Opinion
Years ago, the manufacturer invested in its own professional EMC laboratory. Not only are test reports generated there, but every finished or delivered batch is checked—usually on a daily basis. Additionally, all products are verified by an independent, renowned expert. Double-checked for double security. The test report and expert opinion can be found below under Downloads.
Cancellation of Order | Request a Free Test Sample
If the shielding material is customized and cut from the roll at the customer’s request in increments of 1,0 linear meters, a return or cancellation of the order is not possible. For comparison purposes, it is possible to request a free material sample of the related magnetic field foils M2A or M2L – please request this BEFORE ORDERING customized goods!
All shielding materials are highly developed special products with outstanding performance. The resale of custom-cut shielding material of this performance class is not possible or only possible with significant economic loss, and therefore legally falls under the exception to the right of withdrawal. By ordering custom-cut linear meters, the right of withdrawal expires; the order implies acceptance of the cancellation policy and a waiver of the right of return.