CEMPROTEC 32 PLC | Powerline, Low-Frequency and Magnetic Field Detector in One Combo Meter
Want to know fast whether alternating electric fields reach your bed, whether a transformer or charger gives off a magnetic field, or whether your powerline adapters really switch off at night? The CEMPROTEC 32 PLC electrosmog detector gives you a quick, ballpark answer. It picks up electric fields up to 90 V/m and magnetic fields up to 3.000 nT between 10 Hz and 5 kHz, plus broadband PLC from 1,6 to 68 MHz. All three at the same time.
Good to know first | a building biology and EMF testing perspective
For electric and magnetic fields, the CEMPROTEC 32 is a quick-check tool, not a precision meter. If you want detail, or need to track down specific RF and low-frequency sources, look at our more advanced SAFE AND SOUND EMF meters or a specialist retailer for professional measuring equipment. You can also call in a building biologist or EMF surveyor you trust.
For powerline (PLC), though, it’s currently the only device in our range that detects this exposure at all. RF meters built for WiFi and cellular don’t cover the 1,6 – 68 MHz band. That’s why we added the CEMPROTEC 32 even without a digital display, and why it’s so useful for electrosensitive people.
CEMPROTEC 32 PLC: Low-Frequency and Powerline Detection in One Device
French manufacturer EPE Conseil developed the CEMPROTEC 32 as the successor to the ESI 22. Each field type has its own antenna and its own row of 7 LEDs, running from green through yellow to red. One glance tells you which type of field is present and roughly how strong it is. If nothing is detected, only the first green LED lights up.
Broadband Powerline / PLC (1,6 – 68 MHz)
Powerline communication (PLC) sends internet through your home’s electrical wiring. Think dLAN or powerline adapters used instead of WiFi. The signal then runs along the cables throughout the house. With the CEMPROTEC 32, you can quickly check whether PLC is active and whether your adapters are really unplugged or switched off at night.
Alternating Electric Field (10 Hz – 5 kHz, 0 – 90 V/m)
Electric fields build up around cables, sockets, switches, power supplies, computers and bedside lamps, even when nothing is switched on. The CEMPROTEC 32 shows you whether a field is present at your bed, desk or sofa.
Alternating Magnetic Field (10 Hz – 5 kHz, 0 – 3.000 nT)
Magnetic fields appear whenever current flows, for example around transformers, phone chargers, fuse boxes or high-voltage power lines. The detector senses in three dimensions, so you don’t need to line it up precisely.
Two Modes: Standard and Full PLC
Standard Mode
Switch it on and the detector shows all three field types side by side, each on its own row. It refreshes every two seconds, and the PLC readings in this mode are averaged values.
Full PLC Mode
A short press on the PLC ONLY button switches to Full PLC mode. All 21 LEDs now show PLC alone, with finer steps starting at 2 µW/m². You get real-time peak values, and the highest reading stays lit for two seconds. There’s also an audio analysis: the tone follows the modulated frequency. A long press on the same button turns the sound on or off.
PLC/dLAN powerline switched off
PLC/dLAN powerline switched on
Standard Mode Reading Chart
Each LED row has 13 levels. Besides the single LEDs, two neighboring LEDs can light up together as an in-between step (G = green, Y = yellow, R = red). The table also shows how coarse the steps get, especially at the upper end.
| Level | LED | E-field (V/m) | PLC (µW/m²) | Magnetic field (nT) |
|---|---|---|---|---|
| 0 | G1 | 0 | 0 | 0 |
| 1 | G1 + G2 | 7 | 18 | 25 |
| 2 | G2 | 14 | 45 | 65 |
| 3 | G2 + Y1 | 19 | 80 | 110 |
| 4 | Y1 | 24 | 120 | 155 |
| 5 | Y1 + Y2 | 29 | 165 | 200 |
| 6 | Y2 | 33 | 220 | 260 |
| 7 | Y2 + Y3 | 38 | 330 | 350 |
| 8 | Y3 | 44 | 550 | 470 |
| 9 | Y3 + R1 | 52 | 800 | 800 |
| 10 | R1 | 60 | 1.100 | 1.250 |
| 11 | R1 + R2 | 69 | 1.400 | 1.800 |
| 12 | R2 | 79 | 1.700 | 2.400 |
| 13 | R2 + R3 | 90 | 2.000 | 3.000 |
Full PLC Mode Reading Chart
| Level | PLC (µW/m²) | Level | PLC (µW/m²) |
|---|---|---|---|
| 0 | 0 | 11 | 325 |
| 1 | 2 | 12 | 425 |
| 2 | 5 | 13 | 575 |
| 3 | 15 | 14 | 775 |
| 4 | 30 | 15 | 1.025 |
| 5 | 50 | 16 | 1.300 |
| 6 | 70 | 17 | 1.575 |
| 7 | 100 | 18 | 1.850 |
| 8 | 140 | 19 | 2.150 |
| 9 | 190 | 20 | 2.450 |
| 10 | 250 | 21 | 2.750 |
How to Do a Quick EMF Check
- Switch it on: The detector starts in Standard mode and briefly shows the battery level.
- Extend your arm slightly: Hold the detector about 50 cm (20 inches) away from your body, because your body affects the reading.
- Walk slowly through each room: Pay special attention to the bedroom, living room and workspace.
- Inside or outside? If you can, cut the power to the house briefly and repeat your walk-through. If the reading stays the same, the field is more likely coming from outside. If it drops, the source is probably your own wiring.
- Compare roughly: Check before and after a measure like a demand switch, shielding or grounding to see whether the level changes.
Who Is the CEMPROTEC 32 For (and Who Is It Not For)?
A good fit if you want to
- check whether powerline signals and frequencies are present, or really off at night
- find out as an electrosensitive person whether powerline signals are running on the wiring in your home or from the neighborhood
- run a quick, approximate check at home or in the office
- get a first impression of your surroundings, for example before buying or renting a home
- take it on the road, for example to a hotel room
Not a good fit if you need
- precise measurements of electric and magnetic fields, or targeted searches for individual sources
- expert reports or comparisons with limit and guideline values
- WiFi, DECT, Bluetooth, cellular or 5G readings. For those, you need an RF meter
What this means for electrosensitive people
For electric and magnetic fields, the CEMPROTEC 32 gives you no digital readout, only LED steps. The jumps between steps can be big. For magnetic fields, it goes from 470 to 800 nT. If you react to weak fields, add a meter with a digital display like the SAFE AND SOUND EM3. For powerline PLC/dLAN, on the other hand, the CEMPROTEC 32 is currently the only device in our range that makes this exposure visible. If you’re electrosensitive and want to rule out PLC as a possible trigger, it’s a valuable tool.
Before You Buy: What to Know
According to the manufacturer, the CEMPROTEC 32 is a detector, not a measuring instrument. It shows trends and approximate values. For exact figures, you need a meter with a digital display or a building biologist. The unit is calibrated at 20 °C and 45% humidity. Store it in a dry place and keep it out of children’s reach.
Technical Specifications
| Manufacturer | EPE Conseil, France |
|---|---|
| Model | CEMPROTEC 32 (PLC), successor to the ESI 22 |
| Alternating electric field | 10 Hz – 5 kHz, 0 – 90 V/m, 13 levels |
| Alternating magnetic field | 10 Hz – 5 kHz, 3D, 0 – 3.000 nT, 13 levels |
| Powerline (PLC), Standard mode | 1,6 – 68 MHz, 0 – 2.000 µW/m², 13 levels, averaged values |
| Powerline (PLC), Full PLC mode | 1,6 – 68 MHz, 2 – 2.750 µW/m², 21 levels, peak values with 2 s peak hold |
| Display | 3 rows of 7 LEDs (green, yellow, red), no digital display |
| Audio | audio PLC analysis, can be switched off |
| Refresh rate | every 2 seconds (Standard mode), sampling rate approx. 20 kHz |
| Power supply | 1 × 9 V battery, max. 50 mA, battery level shown at startup |
| Power saving | automatic shut-off after 20 minutes |
| Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
| Dimensions | 179,5 × 46 × 32,2 mm |
| Weight | 80 g |
| Certification | CE |
| Origin | Made in France |
FAQ | Common Questions About the CEMPROTEC 32
It detects alternating electric fields up to 90 V/m and magnetic fields up to 3.000 nT between 10 Hz and 5 kHz, plus broadband powerline (PLC) from 1,6 to 68 MHz. In Standard mode, it shows all three at once as rough LED levels.
With some limits, but yes, especially because of powerline. For electric and magnetic fields, it only gives rough steps with no digital display, so we recommend adding the SAFE AND SOUND EM3. Broadband PLC, though, is something only the CEMPROTEC 32 detects in our range. RF meters like the SAFE AND SOUND PRO 2 don’t cover that frequency band.
No. The manufacturer classes it as a detector. It gives you trends and approximate values, which works well for a quick check and a first impression. For precise measurements, you need a meter with a digital display.
No. The CEMPROTEC 32 doesn’t pick up high-frequency radio signals like WiFi, DECT, Bluetooth, cellular or 5G. For those, you need an RF meter like the SAFE AND SOUND PRO 2.
PLC (powerline communication) sends internet through your electrical wiring, for example with DLAN adapters. The signal then spreads throughout the house. With the CEMPROTEC 32, you can quickly see whether PLC is active and whether your adapters are really off at night.
Only if the meter or gateway communicates via broadband PLC in the 1,6 – 68 MHz range. It doesn’t pick up narrowband communication in the kilohertz range or radio signals.
Keep your arm slightly extended, with the detector about 50 cm (20 inches) from your body. Otherwise, your body affects the reading. Walk slowly, since the detector refreshes every two seconds.
One 9 V battery, and it’s included. The detector shows the battery level at startup and shuts off automatically after 20 minutes. If you use it often, a rechargeable 9 V battery is the better choice.
Yes. Press and hold the PLC ONLY button to switch the speaker off or back on.